energy efficiency

Energy Modelling and Design

Submitted by admin on

The house was modelling in both IES and Accurate. The NatHERS report I did for certification is attached. This does not really try to model the house performance, but just shows it's a least 7 stars. Due to AccuRate limitations, PCMs and building sealing cannot be accurately modelled.

Update 17/9/2016: We have just finished the first Winter. This is The model did not account for a large tree to the NW of the tree, which blocks Winter (and Summer) sun. Generally no heating was required even at night. Some nights were cold and we used a terrible 1kW electric heater for morning warm-up. This was run for about 2 hours per day over 20 days. It runs about 30% of the time when on. This is 4.3 MJ/m²/year (same as modelled figure). It appears the tree's shade (lack of solar gain) is 'cancelling out' the PCM and building sealing.

Accurate was good to test options: it's faster but less sophiscated compared to IES (or EnergyPlus, etc). The summary of modelling is:

  • IES and FR5 results are significantly different.It is difficult to get to the bottom of why - I gave up quickly.
  • Shading is important (Scenario 3 to 4)
  • Ceiling fans are great
  •  Insulation (particularly floor) is good for heating
  • Thermal mass is good (even in Brisbane).
  • If you do all this the above, super windows and superheavyweight provide only minor benefits.

The detailed results are below:

And as HTML:







Name Note Walls
R_total
Roof
R_total
Floor
R_ttal
Windows Heat
MJ/m²
Cool
MJ/m²
Total
MJ/m²
Stars
2 Bad windows This is NCC minimum without shading 2.8 4.1 0.0 U7 SHGC 0.77 31 183 214
3 Add shading This is NCC minimum  2.8 4.1 0.0 U7 SHGC 0.77 31 148 179
4 Add deck shading   2.8 4.1 0.0 U7 SHGC 0.77 39 96 135 ★★
5 Add better windows   2.8 4.1 0.0 U5 SHGC .50 39 73 112 ★★☆
6 Add more insulation   4.5 6.0 2.0 U5 SHGC .50 11 70 81 ★★★☆
7 Add ceiling fans   4.5 6.0 2.0 U5 SHGC .50 12 43 55 ★★★★☆
9 Add movable shading lourves   4.5 6.0 2.0 U5 SHGC .50 5 46 51 ★★★★★
10 Add detailed east/west window shading   4.5 6.0 2.0 U5 SHGC .50 4 43 47 ★★★★★
11 Add lighted coloured roof and walls   4.5 6.0 2.0 U5 SHGC .50 4.3 41 45.3 ★★★★★
14 Add medium weight walls and floor Final rating 4.5 6.0 2.0 U5 SHGC .50 4.7 39 43.7 ★★★★★☆
12 Test only: Super windows  Gets worse - do not use 4.5 6.0 2.0 U2.7 SHGC0.64 0.7 48 48.7 ★★★★★

 

 